2024 Updates For the Latest H12-425_V2.0-ENU Free Exam Study Guide!
Best H12-425_V2.0-ENU Exam Preparation Material with New Dumps Questions
NEW QUESTION # 140
Which of the following functions or components does the UPS6000-E (50kVA power module) come standard with? (Multiple choice)
- A. Dry contact communication card
- B. SNMP function
- C. Parallel function
- D. Bus synchronization control function
Answer: A,B,C,D
NEW QUESTION # 141
If the battery charge current limit coefficient of the UPS5000-E is set to 0.1C10, which of the following statements about this parameter is true?
- A. The battery float charge current is 0.1C10.
- B. The batten/ charge current is always 0.1C10.
- C. The maximum battery charge current is 0.1C10.
- D. The maximum batten/ charge current is 0.1C10.
Answer: D
NEW QUESTION # 142
The skylight actuator can control the reversing skylight of the closed channel of the modular data center.
- A. TRUE
- B. FALSE
Answer: A
NEW QUESTION # 143
When calculating the battery capacity, the battery discharge capacity system at different backup time is the same.
- A. False
- B. True
Answer: A
NEW QUESTION # 144
FusionModule500&FusionModule800 remote WEB interface monitoring must be configured with unified network management software.
- A. False
- B. True
Answer: B
NEW QUESTION # 145
What is the maximum capacity of the power module of the UPS5000-E?
- A. 30kVA
- B. 50kVA
- C. 20kVA
- D. 40kVA
Answer: B
NEW QUESTION # 146
Which of the following measures does the NetEco management system take to ensure the security of the software platform and prevent the leakage of business sensitive data? (Multiple choice)
- A. Security reinforcement and vulnerability prevention for operating systems, databases, and management systems
- B. The management system passes the security scan of anti-virus software
- C. The transmission channel between the management system and the collector adopts encrypted transmission mode
- D. User password is encrypted
Answer: A,B,C,D
NEW QUESTION # 147
Modifying the micro-module layout view on ECC800 supports simultaneous editing by ( ) users.
- A. 0
- B. 1
- C. 2
- D. 3
Answer: C
NEW QUESTION # 148
One sunroof actuator can drive up to () sunroof solenoid valves at the same time.
- A. 0
- B. 1
- C. 2
- D. 3
Answer: D
NEW QUESTION # 149
During the use of the battery, in order to balance the capacity loss caused by the start-up and discharge of the battery, it is necessary to carry out a continuous and long-term constant voltage charging of the battery, which is called ().
- A. Self-discharge
- B. Charging test
- C. Equalizing Charge
- D. Charging
Answer: D
NEW QUESTION # 150
NETCOL9000-A100KW is a dual system, and the standard configuration is a single indoor unit connected to an outdoor unit.
- A. False
- B. True
Answer: A
NEW QUESTION # 151
When UPS5000-E shares a battery pack, the battery capacity parameter of each UPS is set to the total capacity of the entire battery pack.
- A. TRUE
- B. FALSE
Answer: A
NEW QUESTION # 152
All fire-fighting cables running in the FusionModule1000 are covered with metal hoses, and the ends of the pipes are protected by wire sleeves to avoid damage to the fire-fighting cables in the event of a fire.
- A. False
- B. True
Answer: B
NEW QUESTION # 153
Which of the following does the UPS5000-E-400K-FM input line voltage support? (Multiple choice)
- A. 415V
- B. 380V
- C. 220V
- D. 400V
Answer: A,B,D
NEW QUESTION # 154
The skylight actuator can control the reversing skylight of the closed channel of the modular data center.
- A. TRUE
- B. FALSE
Answer: A
NEW QUESTION # 155
NetCol8000-A013U 13kW small cooling capacity temperature control product adopts DC inverter compressor.
- A. False
- B. True
Answer: B
NEW QUESTION # 156
The () components of Huawei NETCOL5000-A in-line precision air conditioner are optional parts.
- A. Fan
- B. Electric heating
- C. Evaporator
- D. Compressor
Answer: B
NEW QUESTION # 157
When the power density of a single cabinet is greater than 10kl/R, which cooling method is recommended?
- A. Room-level air conditioning
- B. Row-level air-conditioning horizontal air supply airtight channel.
- C. Downstream air from room-level air conditioners
- D. Unsealed channel for horizontal air supply of row-level air conditioner
Answer: B
NEW QUESTION # 158
......